The Intesis KNX air conditioning gateway connects various types of air conditioning units with a KNX system. It is used where central control via KNX is desired, regardless of whether the air conditioner communicates via infrared, Modbus, or a proprietary interface. The gateway translates control commands and status messages between both systems, enabling full integration into building automation.

The control includes all important functions such as operating mode, target temperature, fan speed, and louvre position. These can be addressed via KNX communication objects and integrated into visualisations, logics, or scenes. The gateway also provides feedback, so the current status of the air conditioner is always visible in the KNX system. Compatibility with various manufacturers is ensured through an extensive database or specific communication protocols.

Setup is carried out using ETS software. Numerous communication objects are available there, which can be activated or customised depending on the project requirements. For many functions, there are several object variants, allowing flexible integration into existing KNX structures. Control can be done via push buttons, touch panels, logic modules, or time programmes. Combining with other trades such as lighting or shading is also easily possible.

The gateway supports the definition and execution of scenes. These can either be stored in the device or triggered via KNX. This allows coordinated sequences to be realised, for example for comfort, eco, or night operation. Scene control can be linked with other building functions to create a holistic room climate.

Many models have additional inputs that can be used for external sensors or push buttons. These inputs can also be configured via ETS and integrated into the KNX logic. Some variants also offer integrated temperature sensors, whose measurement values are directly available in the KNX system. This allows the air conditioner to respond to the actual room temperature and not just preset values.

Installation depends on the respective model. IR-based gateways require line of sight to the air conditioner, while wired variants are connected directly to the device’s communication interface. Power supply is usually via the KNX bus; some models also allow external supply via USB or 24 volts. The devices are compactly built and intended for indoor use.

Visual indicators and KNX error objects are available to monitor the operating status. These assist during commissioning and maintenance as they can provide hints about communication problems or incorrect settings. This keeps the system clear and reliable even in complex installations.

The range of data point types is wide. Suitable objects are available for each function, which can be integrated into existing KNX structures. Control can be via push buttons, visualisations, or logic modules. This makes the device suitable for many applications – from private homes to hotels or office buildings where central air conditioning control is required.

Recording operating times is also possible. The device can document how long the air conditioner was active. This information can be used for maintenance schedules or to analyse energy consumption. Additionally, manual control via local operating elements can be deactivated if full control via the KNX system is desired.

The Intesis KNX gateway offers a reliable way to integrate air conditioning units into the KNX world. It supports various communication types, can be flexibly configured, and offers functions that go beyond simple temperature control. This makes it a sensible addition for projects where comfort, efficiency, and central control are priorities.


More detailed information about the specific model can be found in the corresponding datasheet.

BAB-Tec
No
Binary inputs integrated
No
Bluetooth
No
Brand
INTESIS
Casambi
No
Class
Climate gateway
DALI
No
ENOcean
No
External power supply
No
free@home
No
Gira One
No
Hager KNXeasy
No
Infrared transmitter
No
JUNG HOME
No
KNX
Yes
KNX-RF
No
KNX-TP
No
Manufacturer item number
INKNXACA001I000
Manufacturer type
INKNXACA001I000
Matter
No
Mbus
No
Modbus
No
Modbus RTU
No
Modbus TCP
No
Mounting type
Installation
Shelly
No
Siemens LOGO!
No
Theben LUXORliving
No
Thread
No
Type of transmission
Cable
Wi-Fi
No
Wiser Home
No
with Netatmo
No
Zigbee
No
Manufacturer information
INTESIS
HMS Industrial Networks GmbH
Emmy Noether Straße 16
76131 Karlsruhe
DE

dadr@hms.se
www.hms-networks.com/de/intesis