KNX gateway for integrating Kostal solar inverters into the KNX bus. The gateway is based on the SunSpec Modbus TCP interface and is compatible with the Kostal inverter series Plenticore and Piko IQ.

Functions

- Publishing generation data on the bus. AC power, daily and total energy, voltage and current per phase, frequency, power factor and inverter temperature – each as a standardised KNX object.

- Display of each PV string. Voltage and current for up to 3 strings – detect a switched-off or defective string via the visualisation.

- Battery monitoring. Charge/discharge power and state of charge (SOC) on the bus for load shifting and emergency power logic.

- Overview of the grid balance. The inverter’s power meter provides the grid feed-in or withdrawal as a signed object – exactly the value needed by the self-consumption logic.

- React without a server. 64 logic functions in the gateway: logic gates with 8 inputs, 4-stage sequences, weekly calendar triggers and mathematical calculations – e.g. surplus over 2 kW for 5 minutes → switch on water heater.

Technical specifications

- Inverters: Kostal Plenticore, Piko IQ (SunSpec Modbus)

- Protocol: SunSpec Modbus TCP interface, Ethernet RJ45

- Data: AC power, energy, voltage, current, frequency, power factor, temperature

- PV strings: 1–3 strings

- Battery: 1 battery – power, state of charge (SOC), total charge/discharge

- Power meter: grid feed-in/grid withdrawal via the inverter’s meter
Amazon Alexa
No
Apple HomeKit
No
BAB-Tec
No
Bluetooth
No
Brand
ELAUSYS
Casambi
No
Class
KNX IP interface
DALI
No
Different bus system
No
Division units
2 TE
ENOcean
No
free@home
No
Gira One
No
Google Assistant
No
Hager KNXeasy
No
Home Assistant
No
Installation location
distribution cabinet
JUNG HOME
No
KNX
Yes
KNX IP-Router
No
KNX-IP-Interface
No
KNX-Line-Coupler
No
KNX-RF
No
KNX-RF media coupler
No
KNX-Secure
No
KNX-TP
Yes
KNX-USB-Interface
No
Manufacturer item number
INV-KNX-KO
Manufacturer type
INV-KNX-KO
Matter
No
Mbus
No
Modbus
No
Modbus RTU
No
Modbus TCP
Yes
Samsung SmartThings
No
Shelly
No
Siemens LOGO!
No
Theben LUXORliving
No
Thread
No
Type of transmission
Cable
Wi-Fi
No
Wiser Home
No
with Netatmo
No
Zigbee
No